Mocking up of Hydro Power Plant to Understand Load Frequency Control

By: Kaushik, Jyoti.
Publisher: New Delhi Journals Pub 2019Edition: Vol.5(2), Jul-Dec.Description: 14-23p.Subject(s): Electrical EngineeringOnline resources: Click here In: International journal of electrical machines & drivesSummary: It is possible to subdivide automatic generation control into fast (primary) and slow (secondary) control modes. The loop dynamics immediately after the load disturbance starts will be determined by AGC's quick primary mode. This fast primary mode of AGC is also known as “Uncontrolled mode” since the speed changer position is unchanged The secondary control acting through the velocity changer and initiated by the appropriate controller is AGC's slow secondary or "Controlled modes." AGC's overall performance in any power system depends on both primary and secondary control loops being properly configured. Therefore AGC's overall performance in any power system depends on the proper design of both the primary control loop (selection of R) and the secondary control loop (selection of additional controller gain). In large power systems, the equilibrium may be obtained inherently by themselves at a point when the new load is compensated by the reduction in power taken by old load plus the power corresponding to kinetic energy extracted from the system. Obviously this equilibrium is obtained at the cost of a reduction in frequency. This equilibrium is self managed by the system and it does not require any governor action. The frequency decline under such a condition is quite large.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology
Archieval Section
Not for loan 2020-2021222
Total holds: 0

It is possible to subdivide automatic generation control into fast (primary) and slow (secondary) control modes. The loop dynamics immediately after the load disturbance starts will be determined by AGC's quick primary mode. This fast primary mode of AGC is also known as “Uncontrolled mode” since the speed changer position is unchanged The secondary control acting through the velocity changer and initiated by the appropriate controller is AGC's slow secondary or "Controlled modes." AGC's overall performance in any power system depends on both primary and secondary control loops being properly configured. Therefore AGC's overall performance in any power system depends on the proper design of both the primary control loop (selection of R) and the secondary control loop (selection of additional controller gain). In large power systems, the equilibrium may be obtained inherently by themselves at a point when the new load is compensated by the reduction in power taken by old load plus the power corresponding to kinetic energy extracted from the system. Obviously this equilibrium is obtained at the cost of a reduction in frequency. This equilibrium is self managed by the system and it does not require any governor action. The frequency decline under such a condition is quite large.


There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha